1kW 12V TBB Power RIIO-II Inverter charger
1kW 12V TBB Power RIIO-II Inverter charger
SKU:RIIO-II-12-1K
Our stock levels are dynamic and can change frequently. If a product appears to be in stock, it may have already sold out. Please contact us if you have any questions about availability. Thank you for your understanding.
Couldn't load pickup availability
1kW 12V TBB Power RIIO-II Inverter Charger
Transformer-Based ย |ย Pure Sine Wave ย |ย Off-Grid & Backup Power
The 1kW 12V TBB Power RIIO-II Inverter Charger is a robust, transformer-based solution designed for seamless backup power, off-grid systems, and energy storage applications. This versatile unit delivers a pure sine wave output, ensuring compatibility with sensitive electronics and appliances. Engineered to handle high surge loads, it provides reliable power for a wide range of residential and commercial needs.
Featuring an ultra-fast 4ms transfer time, the RIIO-II ensures uninterrupted power during grid outages, automatically switching to battery power to keep critical loads operational. It supports parallel operation with up to nine units (three per phase) for expanded power capacity, making it suitable for scalable installations.
KEY CAPABILITY: Integrates backup power, off-grid functionality, and Energy Storage System (ESS) capabilities, ideal for UK homes and businesses seeking energy independence and reliability.
Key Features
| โถย High Surge Power Handling โ Efficiently manages heavy loads with exceptional surge capacity for demanding appliances. |
| โถย Ultra-Fast 4ms Transfer Time โ Ensures uninterrupted power for critical appliances during grid outages. |
| โถย Parallel & Three-Phase Capability โ Expandable up to 9 units (3 per phase) for increased power output in larger installations. |
| โถย ESS & Grid-Tie Integration โ Seamlessly works with E4 LCD Monitor and IC-METER for advanced energy storage and grid-tie functionalities, optimising self-consumption and potential grid feed-in. |
| โถย Automatic Generator Start (AGS) โ Optimises generator operation, starting it only when necessary to save fuel and reduce noise. |
| โถย Power Assist Function โ Supplements a small generator or limited grid supply with battery power to handle heavy loads. |
| โถย ECO Mode for Efficiency โ Reduces self-consumption to prolong battery backup time and maximise energy efficiency. |
| โถย Remote Monitoring โ Monitor performance via the Nova Web and mobile app using the TBB-KIN2 Kinergy-II Wi-Fi module. |
Technical Specifications
| Parameter | Value |
|---|---|
| Nominal Battery Voltage | 12V |
| Continuous Power Output | 1000W / 1000VA (220-240V AC) |
| Peak Power (Surge) | 2000W |
| Output Waveform | Pure Sine Wave |
| Maximum Mains AC Charging Current | 40A |
| AC Transfer Current | 16A |
| Zero Load Power | 12W |
| Peak Efficiency | 89% |
| Protection Index | IP21 |
| Operating Temperature | -20ยฐC to +65ยฐC |
| Humidity | 95% (non-condensing) |
| Altitude | <2000m |
| Dimensions (L x W x H) | 462 x 255 x 144 mm |
| Weight | 11 kg |
Charging & Output Modes
| Mode / Function | Description |
|---|---|
| Inverter Mode | Converts 12V DC battery power to stable 220-240V AC pure sine wave output for household appliances. |
| Charger Mode | Utilises mains AC power to efficiently charge connected 12V battery banks with up to 40A. |
| Bypass Mode | Allows up to 16A (3.68kW) of AC power to pass directly from the input to the loads, bypassing the inverter. |
| Power Assist | Boosts limited AC sources (e.g., small generators or weak grid) by drawing supplemental power from the battery. |
| ECO Mode | Reduces inverter self-consumption to extend battery backup time, ideal for optimising energy usage. |
Typical Applications
| Application | Description |
|---|---|
| Off-Grid Systems | Provides reliable AC power for remote properties, cabins, and holiday homes without grid access. |
| Backup Power Solutions | Ensures continuous power supply during grid failures for essential loads in residential or small business settings. |
| Mobile Applications | Suitable for vehicles, boats, and other mobile setups requiring stable 230V AC power from a 12V battery bank. |
| Energy Storage Systems (ESS) | Integrates with battery storage to maximise self-consumption and manage energy flow for cost savings. |
Built-In Protection Functions
The TBB Power RIIO-II Inverter Charger is equipped with multiple protection features to ensure safe and reliable operation. These include safeguards against output short circuit ย โขย overload ย โขย high battery voltage ย โขย low battery voltage ย โขย high temperature ย โขย input voltage out of range ย โขย input current too high ย โขย and fan block.
Common Questions
What type of battery is compatible with this inverter charger?
The TBB Power RIIO-II is compatible with mainstream lithium battery brands and various generator types, offering flexibility for your power system.
Can I expand the power output of this system?
Yes, the RIIO-II supports parallel operation, allowing you to connect up to three units in a single-phase application or up to nine units in a three-phase configuration for significantly increased power capacity.
Does this inverter charger have grid-tie capabilities?
When integrated with the optional E4 LCD Monitor and IC-METER, the RIIO-II unlocks advanced Energy Storage System (ESS) and grid-tie functionalities, enabling maximised self-consumption and potential grid feed-in.
Is remote monitoring available for the RIIO-II?
Yes, users can easily monitor the inverter charger's performance through the Nova Web platform and mobile app, utilising the TBB-KIN2 Kinergy-II Wi-Fi module for connectivity.
Installation Notes
- Installation should be carried out by a qualified professional to ensure safety and compliance with local regulations.
- Ensure the nominal battery voltage matches the inverter's input voltage (12V in this case).
- Use appropriately sized and shortest possible cables for battery connections to minimise voltage drop and ensure secure contact.
- The unit is designed for indoor use and should not be exposed to rain, snow, or liquids.
- Avoid placing the inverter directly above batteries, as corrosive gases can cause damage.
- Refer to the manufacturer's manual for detailed installation instructions and safety precautions.
Before You Buy
- Verify that the 12V nominal battery voltage and 1kW continuous power output meet your specific system requirements.
- Consider your peak load demands; this unit offers 2000W peak power for starting inductive loads.
- If planning for ESS or grid-tie functionality, ensure you have or intend to acquire the compatible TBB E4 LCD Monitor and IC-METER.
- Assess your space requirements based on the unit's dimensions (462 x 255 x 144 mm) and ensure adequate ventilation.
- For parallel or three-phase configurations, plan for the necessary additional units and wiring.
- Consult with a qualified solar or electrical installer to confirm compatibility with your existing or planned system components.
All specifications are subject to change by the manufacturer. Please verify details with the latest product documentation before purchase. This product is covered by a 5-year manufacturer warranty.
Share